SUI-A2 Series
8*10/100Base extended temperature Dumb Industrial Ethernet Switch
-40~75°C DumbSwitchUL1604
The SUI-A2 series Ethernet switches are designed to operate in the harsh environments at the edge of the network. The SUI-A2 functions at temperatures ranging from -40°C to 75°C (-40°F to 167°F). Whether on the factory floor or the street corner, the SUI-A2 will provide flawless communications when you need it most. Flexibility is the main feature of the SUI-A2, it may be DIN rail, Panel or Rack mounted, and comes with power options to match the applications that require a tough, environmentally hardened, Ethernet switch.
● Complies with IEC61000-6-2 EMC standard
● UL 1604 Class 1, Division 2 Classified for use in hazardous locations (applicable to versions with terminal block power option)
● 2048 MAC addresses
● 768K bits buffer memory
● 10/100Mbps-Full/Half-duplex, Auto-Negotiation, Auto-MDI/MDIX
● Full wire-speed forwarding rate
● Alarms for power and port link failure by relay output
● Redundant 1.5A 24VDC Power inputs or 3A 12VDC Jack
● -40°C to 75°C operating temperature range
● Hardened aluminum case
● Supports DIN-Rail, Panel, or Rack Mounting installation
Technology | 
Regulatory Approvals | 
| Standards: | ISO: | 
| ● IEEE802.3 10Base-T, IEEE802.3u 100Base-TX/100Base-FX, IEEE802.3x | ● Manufactured in an ISO9001 facility | 
| Forward and Filtering Rate: | SAFETY: | 
| ● 14,880pps for 10Mbps | ● UL60950-1, EN60950-1, IEC60950-1 | 
| ● 148,810pps for 100Mbps | ●UL 1604 | 
| Packet Buffer Memory: | ●IEC 61000-6-2 | 
| ● 768K bits | EMI: | 
| Processing Type: | ● FCC Part 15, Class A | 
| ● Store-and-Forward | ● EN61000-6-3 | 
| ● Half-duplex back-pressure and IEEE802.3xfull-duplex flow control | EN55022 | 
| Address Table Size: | EN61000-3-2 | 
| ● 2048 MAC addresses | EN61000-3-3 | 
| Latency: | EMS: | 
| ● Less than 7.1µs | ● EN61000-6-2 | 
Power | 
● EN61000-4-2 (ESD Standards) | 
| Input: | Contact: + / – 4KV; Criteria B | 
| ● Input Voltage: 12VDC (Power Jack); 12 to 48VDC (Terminal Block) | Air: + / – 8KV; Criteria B | 
| ● Input Current: 3A Max. (Power Jack); 1.5A Max. (Terminal Block) | ● EN61000-4-3 (Radiated RFI Standards) | 
| Power Consumption: | 10V/m, 80 to 1000MHz; 80% AM Criteria A | 
| ● 2.4W Max. 0.2A@12VDC, | ● EN61000-4-4 (Burst Standards) | 
| ● 0.1A@24VDC, 0.05A@48VDC | Signal Ports: + / – 4KV; Criteria B | 
Mechanical | 
D.C. Power Ports: + / – 4KV; Criteria B | 
| Casing: | A.C. Power Ports: + / – 4KV; Criteria B | 
| ● Aluminum case | ● EN61000-4-5 (Surge Standards) | 
| Dimensions: | Signal Ports: + / – 1KV; Line-to-Line; Criteria B | 
| ● 50mm (W) x 110mm (D) x 136mm (H) | D.C. Power Ports: + / – 0.5KV; Line-to-earth; Criteria B | 
| (1.97″ (W) x 4.33″ (D) x 5.35″ (H)) | A.C. Power Ports: + / – 2KV; Line-to-earth; Criteria B | 
| Weight: | ● EN61000-4-6 (Induced RFI Standards) | 
| ● 0.8Kg (1.76lbs.) | Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
| Installation: | D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
| ● DIN-Rail Mounting, Rack Mounting | A.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
Interface | 
● EN61000-4-8 (Magnetic Field Standards) | 
| Ethernet Port: | 30A/m @ 50, 60Hz; Criteria A | 
| ● 10/100Base-TX: 8 ports | Environmental Test Compliance: | 
| ● 100Base-FX: 0 or 1 ports | ● IEC60068-2-6 Fc (Vibration Resistance) | 
| LED Indicators: | 5g @ 10~150KHz, Amplitude 0.35mm (Operation/Storage/Transport) | 
| ● Per Unit: Power Status (Power 1, Power 2, Fault) | ● IEC60068-2-27 Ea (Shock) | 
| ● Per Port: 10/100TX,100FX: Link/Activity | 25g @ 11ms (Half-Sine Shock Pulse; Operation) | 
| Alarm Contact: | 50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport) | 
| ● One relay output with current 1A@24VDC | ● IEC60068-2-32 Ed (Free Fall) | 
Environment | 
1M (3.281ft.) | 
| Operating Temperature: | |
| ● -40°C to 75°C (-40°F to 167°F) | |
| ● Tested @ -40°C to 85°C (-40°F to 185°F) | |
| Storage Temperature: | |
| ● -40°C to 85°C (-40°F to 185°F) | |
| Ambient Relative Humidity: | |
| ● 5% to 95% (non-condensing) | 
| SUI-A2008E | 8*10/100TX Unmanaged extended temperature industrial Ethernet Switch | 
| SUI-A2108E-M-SC | 8*10/100TX+1*100FX(Multi mode;SC;2Km) Unmanaged extended temperature industrial Ethernet Switch | 
| SUI-A2108E-S-SC20 | 8*10/100TX+1*100FX(Single mode;SC;20Km) Unmanaged extended temperature industrial Ethernet Switch | 
| Designation | Typical Distance | Nominal Wavelength | Cable Type | Connector | Power Budget | 
| 100Base-FX | 2 Km | 1310 nm | 62.5/125 MM | ST | 15 dB | 
| 100Base-FX | 2 Km | 1310 nm | 62.5/125 MM | SC | 15 dB | 
| 100Base-FX | 20 Km | 1310 nm | 10/125 SM | ST | 19 dB | 
| 100Base-FX | 20 Km | 1310 nm | 10/125 SM | SC | 19 dB | 
| 100Base-FX | 40 Km | 1310 nm | 10/125 SM | ST | 30 dB | 
| 100Base-FX | 40 Km | 1310 nm | 10/125 SM | SC | 30 dB | 
| 100Base-FX | 60 Km | 1310 nm | 10/125 SM | ST | 33 dB | 
| 100Base-FX | 70 Km | 1310 nm | 10/125 SM | SC | 34 dB | 
| 100Base-FX | 80 Km | 1550 nm | 10/125 SM | ST | 29 dB | 
| 100Base-FX | 90 Km | 1550 nm | 10/125 SM | SC | 32 dB | 
| MM: | Multi mode | 
| SM: | Single mode | 
| Installation: | DIN Rail (mounting kit is included) | 
| Power Connector: | Terminal Block |