SUI-A1 Series
16 * 10/100Base extended temperature Dumb Industrial Ethernet Switch
-40~75°CDumbSwitchUL508
The SUI-A1 series Industrial Ethernet switches are designed to operate in the harsh environments at the edge of the network. The SUI-A1 series functions at temperatures ranging from -40°C to75°C, whether on the factory floor or the street corner, the SUI-A1 series will provide flawless communications when you need it most. The SUI-A1 series is a switch with the flexibility of sixteen 10/100TX Ethernet ports that may be configured in a variety of different copper and fiber optic interfaces. It provides fourteen 10/100TX copper ports plus two 100FX ports. Flexibility is the main feature of the SUI-A1 series, it may be DIN rail or panel mounted.
Technology | 
Regulatory Approvals | 
| Standards: | ISO: | 
| ● IEEE802.3 10Base-T, IEEE802.3u 100Base-TX/100Base-FX, IEEE802.3x | ● Manufactured in an ISO9001 facility | 
| Forward and Filtering Rate: | SAFETY: | 
| ● 14,880pps for 10Mbps | ● UL508, EN60950-1, IEC60950-1 | 
| ● 148,810pps for 100Mbps | EMI: | 
| Packet Buffer Memory: | ● FCC Part 15, Class A | 
| ● 1.625M bits | ● EN61000-6-3 | 
| Processing Type: | EN55022 | 
| ● Store-and-Forward | EN61000-3-2 | 
| ● Half-duplex back-pressure and IEEE802.3xfull-duplex flow control | EN61000-3-3 | 
| Address Table Size: | EMS: | 
| ● 4096 MAC addresses | ● EN61000-6-2 | 
Power | 
● EN61000-4-2 (ESD Standards) | 
| Input: | Contact: + / – 4KV; Criteria B | 
| 
 ● Input Voltage: 12 to 48VDC (Terminal Block); 12VDC (DC Jack)  | 
Air: + / – 8KV; Criteria B | 
| Power Consumption: | ● EN61000-4-3 (Radiated RFI Standards) | 
| ● 8.4W Max , 0.7A @12VDC | 10V/m, 80 to 1000MHz; 80% AM Criteria A | 
| ● 0.35A@24VDC,0.175A@48VDC | ● EN61000-4-4 (Burst Standards) | 
| Power Supply References: | Signal Ports: + / – 4KV; Criteria B | 
| ● Terminal Block: 12 to 24VDC, 1.5A | D.C. Power Ports: + / – 4KV; Criteria B | 
| Overload Current Protection: | A.C. Power Ports: + / – 4KV; Criteria B | 
| ● Yes | ● EN61000-4-5 (Surge Standards) | 
| Reverse Polarity Protection: | Signal Ports: + / – 1KV; Line-to-Line; Criteria B | 
| ● Yes | D.C. Power Ports: + / – 0.5KV; Line-to-earth; Criteria B | 
Mechanical | 
A.C. Power Ports: + / – 2KV; Line-to-earth; Criteria B | 
| Casing: | ● EN61000-4-6 (Induced RFI Standards) | 
| ● Aluminum case | Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
| ● IP30 | D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
| Dimensions: | A.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A | 
| ● 75.5mm (W) x 110mm (D) x 135mm (H) | ● EN61000-4-8 (Magnetic Field Standards) | 
| (2.98″ (W) x 4.33″ (D) x 5.31″ (H)) | 30A/m @ 50, 60Hz; Criteria A | 
| Weight: | Environmental Test Compliance: | 
| ● 0.87Kg (1.92lbs.) | ● IEC60068-2-6 Fc (Vibration Resistance) | 
| Installation: | 5g @ 10~150KHz, Amplitude 0.35mm (Operation/Storage/Transport) | 
| ● DIN-Rail, Panel Mounting | ● IEC60068-2-27 Ea (Shock) | 
Interface | 
25g @ 11ms (Half-Sine Shock Pulse; Operation) | 
| Ethernet Port: | 50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport) | 
| ● 10/100Base-TX: 16, 15 or 14 ports | ● IEC60068-2-32 Ed (Free Fall) | 
| ● 100Base-FX: 0, 1 or 2 ports | 1M (3.281ft.) | 
| LED Indicators: | |
| ● Per Unit: Power Status (Power1, Power2, Power3) | |
| ● Per Port: 10/100TX, 100FX: Link/Activity | |
| Alarm Contact: | |
| ● One relay output with current 1A@24VDC | |
Environment | 
|
| Operating Temperature: | |
| ● -40°C to 75°C (-40°F to 167°F) | |
| Storage Temperature: | |
| ● -40°C to 85°C (-40°F to 185°F) | |
| Ambient Relative Humidity: | |
| ● 5% to 90% (non-condensing) | 
| SUI-A1016E | 16 * 10/100TX unmanaged Ethernet Switch | 
| SUI-A1115E-M-SC | 15 * 10/100TX + 1 * 100FX(multi mode, SC 2Km) unmanaged Ethernet Switch | 
| SUI-A1115E-S-SC20 | 15 * 10/100TX + 1 * 100FX(single mode, SC 20Km) unmanaged Ethernet Switch | 
| MM: | Multi mode | 
| SM: | Single mode | 
| Installation: | DIN Rail (mounting kit is included) | 
| Power Connector: | Terminal Block |