Technology
|
Regulatory Approvals
|
Standards: |
ISO: |
● IEEE802.3 10Base-T, IEEE802.3u 100Base-TX/100Base-FX, IEEE802.3x |
● Manufactured in an ISO9001 facility |
Forward and Filtering Rate: |
SAFETY: |
● 14,880pps for 10Mbps |
● UL60950-1, EN60950-1, IEC60950-1 |
● 148,810pps for 100Mbps |
EMI: |
Packet Buffer Memory: |
● FCC Part 15, Class A |
● 384K bits |
● EN61000-6-3 |
Processing Type: |
EN55022 |
● Store-and-Forward |
EN61000-3-2 |
● Half-duplex back-pressure and IEEE802.3xfull-duplex flow control |
EN61000-3-3 |
Address Table Size: |
EMS: |
● 2048 MAC addresses |
● EN61000-6-2 |
Latency: |
● EN61000-4-2 (ESD Standards) |
● Less than 5.1µs |
Contact: + / – 4KV; Criteria B |
Power
|
Air: + / – 8KV; Criteria B |
Input: |
● EN61000-4-3 (Radiated RFI Standards) |
● Input Voltage: 12 to 48VDC (Terminal Block) |
10V/m, 80 to 1000MHz; 80% AM Criteria A |
Power Consumption: |
● EN61000-4-4 (Burst Standards) |
● 2.4W Max. 0.2A@12VDC, |
Signal Ports: + / – 4KV; Criteria B |
● 0.1A@24VDC, 0.05A@48VDC |
D.C. Power Ports: + / – 4KV; Criteria B |
Power Supply References: |
A.C. Power Ports: + / – 4KV; Criteria B |
● Terminal Block: 12 to 24VDC, 1.5A |
● EN61000-4-5 (Surge Standards) |
Overload Current Protection: |
Signal Ports: + / – 1KV; Line-to-Line; Criteria B |
● Yes |
D.C. Power Ports: + / – 0.5KV; Line-to-earth; Criteria B |
Reverse Polarity Protection: |
A.C. Power Ports: + / – 2KV; Line-to-earth; Criteria B |
● Yes |
● EN61000-4-6 (Induced RFI Standards) |
Mechanical
|
Signal Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A |
Casing: |
D.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A |
● Plastic case |
A.C. Power Ports: 10Vrms @ 0.15~80MHz; 80% AM Criteria A |
● IP30 |
● EN61000-4-8 (Magnetic Field Standards) |
Dimensions: |
30A/m @ 50, 60Hz; Criteria A |
● 25mm (W) x 70mm (D) x 110mm (H) |
Environmental Test Compliance: |
(0.99″ (W) x 2.76″ (D) x 4.33″ (H)) |
● IEC60068-2-6 Fc (Vibration Resistance) |
Weight: |
5g @ 10~150KHz, Amplitude 0.35mm (Operation/Storage/Transport) |
● 0.2Kg (0.44lb.) |
● IEC60068-2-27 Ea (Shock) |
Installation: |
25g @ 11ms (Half-Sine Shock Pulse; Operation) |
● DIN-Rail Mounting |
50g @ 11ms (Half-Sine Shock Pulse; Storage/Transport) |
Interface
|
● IEC60068-2-32 Ed (Free Fall) |
Ethernet Port: |
1M (3.281ft.) |
● 10/100Base-TX: 5, 4 or 1 ports |
|
● 100Base-FX: 0 or 1 ports |
|
LED Indicators: |
|
● Per Unit: Power Status (Power 1, Power 2) |
|
● Per Port: 10/100TX,100FX: Link/Activity (Green), Speed (Yellow) |
|
Environment
|
|
Operating Temperature: |
|
● -10°C to 60°C (14°F to 140°F) |
|
Storage Temperature: |
|
● -25°C to 85°C (-13°F to 185°F) |
|
Ambient Relative Humidity: |
|
● 5% to 90% (non-condensing) |
|